1. A continuous loop Gas
Control Valve positioning plate cable fault locator board and control board is disconnected cables, fault or short circuit. Such as persistent cycle time over two minutes, the gas control valve to stop the rotation, and displayed on the screen -E1- and blinks. 2. Locate the board is damaged gas control valve leakage, corrosion, or the Hall element positioning plate full damage, leading to not be located. 3. The magnet damage of Gas
Grill Control Valve or damage to the magnet magnetic insufficient, and the Hall element is positioned plate can not produce a signal. Magnets can not be used in strong vibration or strong magnetic fields such as environment.
Control valve consists of two major assemblies components: body assembly and actuator assembly (or actuator systems), is divided into four series: single-seat series control valves, control valves seater series, sets cylinder series control valves and self-series control valve.
2015年3月21日星期六
2015年3月17日星期二
The problems of gas heater valve in working process
gas heater control valve does not operate a) the system does not run A, flow-type softening valve, run the flow is set to 0. B, automatic filter Gas
Grill Control Valve in the F-00 to F-01 or greater. "Run" position C, the positioning plate of the Hall element is damaged. The main cause of valve leakage. D, F78 distribution valve gas heater control valve inlet or drain plug. Automatic gas heater control valve does not operate A, main board failure. B, motor, motor control board is connected with the motor pinion or transmission damage, leading to the terminal large gear on the motor can not drive the spool rotation. C, with a hand on the handwheel Gas
Control Valve, such as F63, F67, F68, intermediate gear and motor gear or gear wheel slip terminal. D, water quality is poor, resulting in a large resistance between the sealing sheet, the motor does not move with. E, the valve is stuck between objects or large gear motor gear and terminal objects resting motor with fixed. F, a foreign body water, damaged or stuck valve. G, the water pressure is high, the motor does not move with.
2015年3月13日星期五
Gas heater control valve does not work
1. softener or Gas Control Valve no longer a student), the controller can not control the rotation of the motor A, the gas heater control valve power interruption: damage to equipment failure or power adapter (no display screen). If no power but no display screen, can be used the same type of power supply for testing; now Run the new Propane Control Valve mainly uses two types of power adapters, output voltage and current are DC12V, 1500mA and DC24V, 1500mA. B, motor and motherboard cable shorted. Water immersion or valve leakage control panel, this phenomenon can occur when such installation. C, the motherboard is damaged and can not control the rotation of the motor. D, motor damage. Mainly caused by patio heater control valve leakage. 2), the regeneration time setting unreasonable time or flow regeneration program shows yet to come, but the actual water hardness has been exceeded. A, time type, the regeneration time is set incorrectly, exceed the maximum of water softener system cycle. If this should be renewable once for two days, is set to 20 days renewable once. B, flow type, the total flow is not cut down or decreasing slower than the actual speed, the meter is damaged, no instantaneous flow. For two main reasons: ① suck iron impeller is stuck or foreign body material, can not be rotated. ② meter meter cord is damaged or loose with the motherboard socket. ③ control board failure. 3), the motor can not control spool rotation.
2015年3月9日星期一
The use of gas heater control valve
Pressure range of different operating pressure range of gas heater valve is lower than the hydraulic valves. Working pressure gas heater valve is usually less than 10bar, few can reach within 40bar. However, working pressure of the hydraulic valves are very high (usually less than 50Mpa). If the gas heater valve in excess of the maximum allowable pressure. Often a serious accident. Use different characteristics than the general gas heater valves hydraulic valves compact, light weight, easy to integrate installation, high Gas
Heater Control Valve operating frequency, long service life. gas heater valve forward low power, miniaturization direction, low-power solenoid valve has appeared only 0.5W of power. Can be directly connected with the computer and PLC programmable controller can also be mounted on a printed circuit board with electronic devices, connected via a standard gas-electric circuit board, save a lot of wiring for pneumatic industrial robots, complex manufacturing assembly line and other occasions.
2015年3月5日星期四
Performance comparison gas heater control valves and hydraulic valves
Energy may be different pneumatic components and devices Pneumatic gas station method (a) use, depending on requirements and control points to adjust their working pressure Gas Heater Valve. Hydraulic valves are equipped with the return line to facilitate the collection of used hydraulic oil tank. gas heater control valve can be directly compressed air to the atmosphere through the exhaust port. (B) leakage of hydraulic Gas Control Valve for the different requirements of outward leakage demanding, but a small amount of leakage of internal components is allowed. gas heater control valve, the valve seal in addition to the gap, in principle, allow the internal leakage. Internal pneumatic valve leak there is a risk of accidents. For pneumatic tube, it allows a little leakage; leaking hydraulic pipes will cause the system pressure drop and pollution of the environment. (C) for lubrication requirements of different hydraulic system working medium for hydraulic oil, Gas Heater Control Valve there is no requirement for lubrication; pneumatic system working medium is air, the air without lubrication, so many pneumatic valves require mist lubrication. Gas heater control valve parts should be the choice of materials less susceptible to water corrosion, rust, or to take the necessary measures.
2015年3月2日星期一
The analysis on gas heater valve
Acetic acid as important chemical intermediates, has been widely used, and its derivatives are hundreds of species. Growing downstream Gas Heater Valve acetate fibers, paints, adhesives and other industries and downstream industry chain development efforts acetate continued to increase for the development of Chinese acetic acid industry provides a good background environment and opportunities.
Because of two devices in the selection and amount of catalyst synthesis loop size respects fundamentally different from the first phase, so the process operation there is a big difference, especially in the gas heater valve synthesis reactor since the circulation line with strict temperature requirements . To be able to achieve the desired operating results, the temperature control loop pipeline between 185 ~ 195 ℃, pressure rating between 2.8 ~ 4.0MPa. But in most of the use of the pipeline is lined with ordinary type PTFE (polytetrafluoroethylene) material plug, when the system is running two to three months time to shut down for maintenance, unable to find the Gas Heater Control Valveclosed, should not be process. Examination revealed plug lined with varying degrees of loss, more serious tear occurred. In order to ensure normal production, this problem is analyzed and processed.
Because of two devices in the selection and amount of catalyst synthesis loop size respects fundamentally different from the first phase, so the process operation there is a big difference, especially in the gas heater valve synthesis reactor since the circulation line with strict temperature requirements . To be able to achieve the desired operating results, the temperature control loop pipeline between 185 ~ 195 ℃, pressure rating between 2.8 ~ 4.0MPa. But in most of the use of the pipeline is lined with ordinary type PTFE (polytetrafluoroethylene) material plug, when the system is running two to three months time to shut down for maintenance, unable to find the Gas Heater Control Valveclosed, should not be process. Examination revealed plug lined with varying degrees of loss, more serious tear occurred. In order to ensure normal production, this problem is analyzed and processed.
2015年2月28日星期六
The introduction of gas heater valve
Below the level of progress of science and technology, China's chemical production automation has also been a rapid promotion, to achieve precise control of flow, pressure, level and temperature, among chemical automatic control system, the control Gas Heater Valve is an important part of the implementation of device, the model and the quality of the installation for the regulation loop regulation quality has a significant impact, if you adjust the selection and application of improper gas heater valve, regulating gas heater valve will be a serious threat to the life, the Water Heater
Gas Valves is serious and even cause the system to stop accidents.
In the development of industrial automation, pneumatic control gas heater valve actuators as a good has been widely used, the kind of control gas heater valve has a reliable action, simple structural features, for the protection of the safe operation of great significance, the following on automatic control for chemical process pneumatic control Gas Heater Control Valve selection and application of in-depth analysis.
In the development of industrial automation, pneumatic control gas heater valve actuators as a good has been widely used, the kind of control gas heater valve has a reliable action, simple structural features, for the protection of the safe operation of great significance, the following on automatic control for chemical process pneumatic control Gas Heater Control Valve selection and application of in-depth analysis.