Control valve consists of two major assemblies components: body assembly and actuator assembly (or actuator systems), is divided into four series: single-seat series control valves, control valves seater series, sets cylinder series control valves and self-series control valve.
2018年6月19日星期二
JELPC offers a variety of Solenoid Valves
JELPC offers a variety of models with different configurations and capabilities, making it easy to find the right Solenoid Operated Valve for your unique application. A very common method of operating directional valves in a pneumatic system is with Solenoid Operated Valves. Recommended for use in systems requiring higher flow rates, a direct acting solenoid is mounted on a larger pneumatic valve and acts as a pilot operator. Upon actuation of the solenoid, pilot pressure shifts the larger valve, directing flow from the input port through the output port.
2018年4月23日星期一
Standard air cylinder Precautions
The standard air cylinder should be noted when installing and adapting:
1.When the load changes in the work, the cylinder with abundant output should be selected.
2. In high temperature or corrosive conditions, the corresponding high temperature or corrosive cylinder should be selected;
3. In the case of large humidity and dust, or where there are water droplets and welding slag, the cylinder should adopt the protective measures to take a sigh.
4. Before the cylinder is connected to the pipe, it is necessary to know the stolen goods in the pipe and prevent the debris from entering the cylinder;
5. The medium of the cylinder shall be filtered by the filter core of 40um and above to be used;
6. In low temperature environment, anti-freeze measures should be taken to prevent water freezing in the system.
7. Before the cylinder is used, it should be operated by no-load test. Before operation, the buffer should be adjusted to the minimum I, and gradually give up, so as not to damage the cylinder;
In the working process, the cylinder should avoid the side load as much as possible, so as to maintain the normal operation of the cylinder and extend the service life;
It is not suitable for the cylinder to be removed for a long time. It should be noted that the surface is rustproof, and the inlet and outlet should prevent the blocking cap.
1.When the load changes in the work, the cylinder with abundant output should be selected.
2. In high temperature or corrosive conditions, the corresponding high temperature or corrosive cylinder should be selected;
3. In the case of large humidity and dust, or where there are water droplets and welding slag, the cylinder should adopt the protective measures to take a sigh.
4. Before the cylinder is connected to the pipe, it is necessary to know the stolen goods in the pipe and prevent the debris from entering the cylinder;
5. The medium of the cylinder shall be filtered by the filter core of 40um and above to be used;
6. In low temperature environment, anti-freeze measures should be taken to prevent water freezing in the system.
7. Before the cylinder is used, it should be operated by no-load test. Before operation, the buffer should be adjusted to the minimum I, and gradually give up, so as not to damage the cylinder;
In the working process, the cylinder should avoid the side load as much as possible, so as to maintain the normal operation of the cylinder and extend the service life;
It is not suitable for the cylinder to be removed for a long time. It should be noted that the surface is rustproof, and the inlet and outlet should prevent the blocking cap.
2018年3月30日星期五
Pneumatic control components
Pneumatic control components are important components of pressure, flow, flow direction and sending signal of compressed air, which are important components of pneumatic circuits and systems. The pneumatic control is known as the pneumatic valve, or valve.
2018年3月21日星期三
The working principle of the steam solenoid valve.
1. The steam solenoid valve is the direct pilot type solenoid valve for the step action, which can be divided into the normal closed solenoid valve and the normally open solenoid valve according to the difference of the opening and closing state when the power is off.
2. The steam solenoid valves, normally closed steam coil after electrify, armature vice valve under the effect of electromagnetic force to drive the valve plug, fluid by the deputy valve on the main valve cup run, reducing the role, the pressure of the main valve cup when the main valve cup pressure was reduced to a certain value, the armature drives the main valve cup, and by using pressure difference and make the main valve cup opening, medium circulation. When the coil is out of power, the electromagnetic force disappears, and the armature is reset due to gravity. At the same time, depending on medium pressure, the main auxiliary valve can be closed tightly.
3. Normally open steam solenoid valves, steam coil electricity due to the suction effect, after moving iron core down, the deputy valve plug pressure, the deputy valve closed, pressure rise within the main valve cup, when the pressure rises to a certain value, the main valve cup of fluctuation pressure difference, due to the electromagnetic effect, moving iron core loss of the main valve cup, the pressure the main valve seat, the valve closed. When the coil is out of power, the electromagnetic suction is zero, the auxiliary valve plug and the iron core are lifted by the spring, the auxiliary valve is opened, the main valve cup is pushed up by the pressure difference, the main valve is opened and the medium is in circulation.
2. The steam solenoid valves, normally closed steam coil after electrify, armature vice valve under the effect of electromagnetic force to drive the valve plug, fluid by the deputy valve on the main valve cup run, reducing the role, the pressure of the main valve cup when the main valve cup pressure was reduced to a certain value, the armature drives the main valve cup, and by using pressure difference and make the main valve cup opening, medium circulation. When the coil is out of power, the electromagnetic force disappears, and the armature is reset due to gravity. At the same time, depending on medium pressure, the main auxiliary valve can be closed tightly.
3. Normally open steam solenoid valves, steam coil electricity due to the suction effect, after moving iron core down, the deputy valve plug pressure, the deputy valve closed, pressure rise within the main valve cup, when the pressure rises to a certain value, the main valve cup of fluctuation pressure difference, due to the electromagnetic effect, moving iron core loss of the main valve cup, the pressure the main valve seat, the valve closed. When the coil is out of power, the electromagnetic suction is zero, the auxiliary valve plug and the iron core are lifted by the spring, the auxiliary valve is opened, the main valve cup is pushed up by the pressure difference, the main valve is opened and the medium is in circulation.
2018年2月8日星期四
Heater Valve Products
A defective heater is a big problem especially during winter. You and
your passengers could experience a "chilling" inconvenience when the
part becomes faulty on a bleak morning ride. See, you could get
frostbites without the warmth provided by the heater. With this kind of
problem, too, you're most likely to catch colds if you're going on a
long trip. So before heading out for the road on a cold day, remember to
check your car heater first. If there's a damaged part, replacement
must be done immediately. The 1 is one of the most important
components that drivers need to check since it's directly involved in
the distribution of hot air inside the cabin. This 1 is connected to
a slide, lever, or dial on the dashboard. By flicking any of these, the
driver is able to control the amount of coolant that the valve directs
to the heater core. To inspect the valve, you have to do a bit of
searching because it's found at the back portion of the engine bay. Now,
when this valve gets damaged, the flow of hot air may cease. And the
worst thing that could happen is that there won't be any warm air
flowing in your car's interior. To avoid this hassle, you must find a
high-quality heater valve replacement as soon as possible. For auto
parts of superior quality, shop only at Auto Parts Warehouse. You'll
surely get the best value for your money if you buy replacement parts
from us.
2018年1月17日星期三
Electric solenoid valves
Electric solenoid valves is an industrial equipment controlled by electromagnetic control. It is an automatic basic element for controlling fluid. Electric solenoid valves belongs to actuator, and is not limited to hydraulic and pneumatic. Adjust the direction, flow, speed and other parameters of the medium in the industrial control system. The solenoid valve can cooperate with different circuits to achieve the expected control, and the accuracy and flexibility of the control can be guaranteed. There are many kinds of solenoid valves. Different solenoid valves play a role in different positions in the control system. The most common ones are one-way valve, safety valve, directional control valve, speed regulating valve and so on.
2017年12月13日星期三
High temperature solenoid valve
High temperature solenoid valve is a kind of forerunner of solenoid valve, type of moving its widely used in shipbuilding industry, testing equipment, heating equipment, hydraulic equipment, in operating temperature above 300 ℃ heat conduction system. In the exhaust system of the pumping pipeline and evaporator of the power station, it is mainly used for the dual automatic adjustment and remote control of the medium in the pipeline.
订阅: