2014年7月23日星期三

gas valves for pressure testing

P1 pressure of compressed air, the latter from the left end of the input port 10 through the throttle valve, pressure drop P2 output. P2's size can be adjusted regulator spring 2,3. Turn the knob clockwise 1, 2, 3 and diaphragm compression spring 5 8 spool down, increasing standpipe metric fitting the opening of the valve port 10 so that P2 increases. If a counter-clockwise rotation of the knob, opening of the valve port 10 is reduced, P2 decreases.
If the transient elevated P1, P2 will subsequently increases, so the pressure in the diaphragm metric tube fittings chamber 6 increases, the thrust generated by the diaphragm 5 is increased accordingly, the destruction of the balance of the original thrust force, the diaphragm 5 up mobile, 12, a small part of the air exhaust vent through the overflow hole 11. While the diaphragm moves, by the action of the return spring 9, the spool 8 is hydraulic ferrule moved upward, off a small intake valve port 10, to increase the throttling effect, the output pressure decreases until reaching a new equilibrium is attained, the output pressure substantially back to the original value. If you enter the instantaneous pressure drop, the output pressure drop, the diaphragm 5 down, down along the spool 8, the intake valve port 10 open big, throttling effect is reduced, so that the output pressure is basically back to the original value. Rotate the knob counterclockwise 1. 2,3 relax the adjusting spring, the gas acting on the membrane 5 is greater than the thrust force of the regulating spring, the diaphragm upwardly curved, by the action of the return spring to close the intake valve port 10. Then rotating the knob 1, the intake air relief valve body seat 4 and the top 8 is disengaged, then 12, vent hole 11 is discharged through the overflow chamber 6 of the diaphragm compressed air, in a non-output state of the valve .

2014年7月16日星期三

Part of the British hydraulic fittings By a combination of control valves, hydraulic components bi-directional lock, flat cut-off valve, check valve, safety valve, safety valve and pressure british hydraulic fittings measurement including high flow valves and other components of the British hydraulic fittings one-way valve. Infusion pipeline system consisting of a high pressure hose. Beams and roof beams dumplings before then, and supported by short column to the top of the beam as a fulcrum banjo bolt fittings, can be 15 degrees or swing to the 'Bu as 19 degrees upward, to improve the situation before contact with the roof beams, so close to the coal wall the roof can be effectively supported, avoiding produced before the end of the roof and cut the top of the phenomenon of channeling partings. In front bezel with anti-chip and jacks composed by the help devices. Necessary work, and can extend the anti-spalling and coal wall close to the device can also be retracted to chinapneumaticcylinders allow British hydraulic fittings shearer drum passed. Top beam is the main component of the bracket bearing, front and front beam pick dumplings, dumplings beam rear end of the cover and then cut the top plays a role in the web of welded nest with four columns, connected with the ball joint stud, two side mounted retractable side guards for block partings and anti-down purposes. Due to its direct contact with the top plate, it requires a sufficient area, and requires a sufficient strength. Cover the top of the beam by the hinge pin and roof beams, the lower end of the connecting rod and the base by four dumplings then, its main role is to bear the roof to give the horizontal component bracket, so the column from lateral bending loads, and to prevent caving Advantech stone fleeing stent to ensure the safety of persons and equipment.

2014年7月15日星期二

Advantages and disadvantages advantages Jic hydraulic fittings bracket covering hydraulic bracket: roof beams short force on the roof of a uniform, controlled from the top frame shift hydraulic fittings suppliers is small, the number of small to support the roof again, help protect the integrity of the roof. Pillar tilt arrangement, a large increase in scope, because the pillars not withstand lateral loads, the stress state is good, not easy to damage. Multiseal metric hose fitting Dagan perfect block device allowing work space and roof, completely separated from the old pond, Jic hydraulic fittings effectively prevent leakage partings, and Chung channeling gangue gangue. Shield hydraulic support for the stable motion mechanism, the horizontal force frame shift caused by the four-bar linkage bear, thus requiring the horizontal thrust of good performance can be achieved with a pressure shift rub the top shelf. Mechanical and hydraulic systems than simple, easy operation and maintenance, work space, large ventilation resistance is inappropriate to have a strong period of pressure and gas emission from large coal.
Reusable hose fitting Detachable hose fittings
When the assembly does not require special equipment, easy to operate, especially for field work, and can be reused, but high prices to customers reusable hose fittings. Withhold reliable high pressure series because the connection has been widely used, but requires special processing assembly withhold equipment, so most customers buy directly hose assembly. Reusable hose fitting for low pressure situations, because of its quick-release for easy maintenance and replacement has been widely used in automotive jic swivel fittings production line, has also been widely used in the mold industry. This is a convenient removable, reusable, sealed modular connectors.reusable hydraulic hose fittings Proved by the production, prolong the service life of corrugated stainless steel hose body 3-8 times. Reusable hose fitting corrugated stainless steel hose wall is thin, approximately 0.5mm, 3-5 times lighter than rubber tube, and difficult to bend into a "dead." Therefore, to be more widely used in petrochemical production. Corrugated stainless steel hose body after a period of time using (generally 1-4 years, the individual is less than 1 year), at the junction hose and pipe, the first rupture, causing media leaks, it is because the hose and flange lamination place, less flexible, because the hose wall is thin, operation, large range of activities, often close to the lamination of the hose to withstand maximum stress on the damaged hose physical testing is often able to identify the hose provide clues to the causes of damage.

2014年7月11日星期五

The use of the gas valves

Overhaul thermocouple can be artificially heated, if the heat can generate electricity, coupled with the solenoid valve, the valve stem when heated press pull well, indicating skiving machine thermocouple intact. Put it back into the water heater, adjust the position of the thermocouple heat heating side of the case to ignite the fire. After the up, down, left, right, several adjustments, when it is in the outer flame metric thread oring face seal fittings fire and have enough heating area, the fire will normally reserved.
1 cut-off valve
According to install shut-off valves premises may be orientation during installation to stem hydraulic ferrule vertical as well. Medium flow direction of medium flow from the bottom of the valve disc valve
Top of the plate, according to media flow arrow on the valve body marked for installation.
2 Gate
In addition valve installed in the Japanese metric thread pipe condition, stem mounted vertically as possible. However, according to the spatial location of the cabin, hand wheel vertically downwards
Installation is also possible. Flow direction is no requirement, but should be considered after the installation instructions can switch easy to observe.
3 Check Valve
Lift check valves should be installed over the valve plate vertically. Swing check valves installed in horizontal pipe, valve disc is rotated upward when opened. Installed in vertical
Straight pipe, valve disc is located in the upper part of the seat. When installing medium flow direction of media flow valve shall be indicated by the arrow on the sign.
4 non-return valve
Closing check valve body should be medium flow arrow on the sign to be installed when you install to stem vertical as well.

Set fire gas valves water heater has two main functions

one is to use it to ignite the main burner; second is to use its uninterrupted heated thermocouple. Thermocouple is a heat can be converted into electrical energy components, installed next to the fire, the heat generated by its current control solenoid hydraulic cutting machine, open fire in the supply channel, so as to achieve the maintenance supply, continued to ignite the fire purposes. Water heaters used for a period of double hose connector time, prone to fire and flame failure can not be sustained. Its causes and treatment methods are as follows.
The gas fire unreasonable or can not maintain the channel conduction is the root cause of the fault.skiving machine If the thermocouple or the solenoid valve failure, fire or clogged nozzles will result in the supply passage barrier. When the thermocouple poor performance, even though it burned red, still no release after the fire when the ignition hand, can not hear the sound operation of the solenoid valve. In addition to external thermocouple failure, cracks or loose electrode leads are not likely to result in sustained ignition failure. If the hand release missing after the fire, but could hear the sound of the solenoid valve is released, it is clogged nozzle, then fire supply pipe can be removed with fine copper wire poke at the dirt can clog. If you have a fire after the hand release, but soon after automatically extinguished, it is caused by reason of the thermocouple. Can try to re-adjust the position of its best heat generally able to troubleshoot.

2014年7月9日星期三

By end-use, the valve can be divided gas valves according to the different uses:

1 breaking with: to connect or disconnect the gas pipeline, such as the cut-off valve, gate valve, ball valve, butterfly valve. 2 ended reuse: to prevent the backflow of gases, such as check valves. 3 adjustment: adjust the gas pressure and flow, such as valves, valve. 4 assignment: to change the flow of the gas, gas distribution, such as the three-way cock, dispensing valve, spool valve. Fourth, according to the driving hydraulic cutting machine mode, depending on the driving mode can be divided into: 1 Manual: With hand wheels, handles, levers or sprockets, etc., there are human-driven, large transmission torque when fitted with worm reduction gear and gear motor 2: With motor or other electrical device driver. 3 air; driven by compressed air. Five, according to the pipe connection points, according to the valve and Interlock SAE Flange pipe connections can be divided; 1 Flanged valves: valve with flanges, valves and pipe with flanged connections. 2 threaded connection valve: Body with internal or external threads, threaded pipe connection using valves. 3 welded connection valve: body with welded joints, valves and pipe with welded connections. 4 clamp connection valve: the valve body with jaws, valves and pipe with clamp connections. 5 card sets connected to the valve: A valve sleeve and pipe connections

According valves gas valves and pipe connections can be divided

1 Flanged valves: valve with flanges, valves and pipe with flanged connections. 2 threaded connection valve: Body with internal or external threads, threaded pipe connection using valves. 3 welded connection valve: body with hydraulic ferrule welded joints, valves and pipe with welded connections. 4 clamp connection valve: the valve body with jaws, valves and pipe with clamp connections. 5 card sets connected to the valve: A valve sleeve and the pipe connections. Use Gas valves are widely used for a variety of city gas valves pipeline network system media pipeline gas, liquefied petroleum gas, natural gas and oxygen. Drive in the form of a manual, worm gear, double hose connector electric, pneumatic, hydraulic, electro-hydraulic actuator linkage, enabling remote control and automatic operation. According to the structure of the main types are: Plug valves, gate valve, globe valve, ball valve - used to turn on or off the gas flow pipe. Check valve (including bottom valve) - used to automatically prevent backflow of gas pipeline. Throttle - for regulating the flow of gas pipelines. Valve - used to automatically reduce the gas pressure inside the equipment and piping. Department of the gas valve through the gap, resulting in the loss of resistance to pressure to achieve the purpose of decompression.

2014年7月7日星期一

According to the structure of the gas valve types are

Plug valves, gate valve, globe valve, ball valve - used to turn on or off the gas flow pipe. Check valve (including bottom valve) - used to automatically prevent backflow of gas pipeline. Throttle - for regulating the flow of gas pipelines. Valve - used to hydraulic hose manufacturers automatically reduce the gas pressure inside the equipment and piping. Department of the gas valve through the gap, resulting in the loss of resistance to pressure to achieve Reduction valve the purpose of decompression. By end-use, the valve can be divided according to the different uses: 1 breaking with: to connect or disconnect the gas pipeline, such as the cut-off valve, gate valve, ball valve, butterfly valve. 2 ended reuse: to prevent the backflow of gases, such as check valves. 3 adjustment: adjust the gas pressure and flow, such as valves, valve. 4 assignment: to change the flow of the gas, gas distribution, such as the three-way cock, dispensing valve, spool valve. Press the drive mode, depending on the driving mode can be divided into: 1 Manual: With hand wheels, handles, levers or sprockets, etc., there are human-driven, large transmission torque when fitted with reduction gear worm gear. 2 Electric: With motor or other electrical device driver. 3 air; driven by compressed air.

gas valves as well as the classification of the following methods:

By structural features, based off the seat relative to the direction of movement can be divided into: 1 door-shaped DKL fitting cut: off pieces move along the seat center. 2 gate shape: off pieces to move along the vertical seat center. 3 cock and ball: ball plunger or closure member is rotating around the center line itself. 4 Swing type: off pieces around the hydraulic hose ends outside of the valve shaft rotation. 5 dish: off pieces of the disc around the axis of rotation of the valve seat. 6 spool type: sliding closure member in a direction perpendicular to the channel.