12 volt solenoid use widely

12 volt solenoid allow remote control of fluid flow from the driver's seat. solenoid valve is open when toggle switch is on, when switched off remains closed regardless of ignition switch position. Use the toggle switch and 16 gauge wire included in the kit to wire the valve. 12 volt solenoid used widely in home appliances,vending machines, game machine,auto door lock,cabinet etc.

2018年9月20日星期四

single coil solenoid valve electric current through the coil creates a magnetic field

solenoid valve is an electromechanical controlled valve. single coil solenoid valve features a solenoid, which is an electric coil with a movable ferromagnetic core in its centre. This core is called the plunger. In rest position, the plunger closes off a small orifice. An electric current through the coil creates a magnetic field. The magnetic field exerts a force on the plunger. As a result, the plunger is pulled toward the centre of the coil so that the orifice opens. This is the basic principle that is used to open and close solenoid valves.

2018年9月6日星期四

Toggle valve has an automatic thermal protector

toggle valve has an automatic thermal protector and operates in the black range for maximum life. toggle valve is a compact design for normally closed and quick on/off service. Moving the handle 90 degrees upwards opens the valve to full flow and stops it firmly in the open position. Shifting the handle position downwards shuts off the valve by spring return. The PTFE soft seat at the tip of the stem provides a positive repetitive seal. solenoid directional valve on and off settings determines whether or not fluid flows past the valve. Well-designed toggle valve should possess the quality that it hinders flow completely when closed while allowing nearly unaffected flow when open. Main goal of a toddle valve is to minimize the effect of pressure when in open position.

2018年8月10日星期五

air flow control valves is suitable for use with a variety of gases and fluids

air flow control valves are used to operate the cylinders single action or double action and to successively activate other valves. Flow regulators are used to adjust the air flow supplied to the valves, the cylinders and engines, and many others. flow control valves may be provided with a check valve ; these types of controllers will resolve the flow in 2 directions. The valve designs and material make them suitable for use with a variety of gases and fluids. Complete valves are available in straight through or 90° degree angle body configurations and are constructed of brass or stainless steel.

2018年7月31日星期二

Two position three way valve permits them to be used for two completely different flow patterns

Two position three way valve are used to divert flow in process piping systems.  The valves incorporate a unique design that permits them to be used for two completely different flow patterns. Valves can be installed so that the bottom port is the common or inlet port.  The flow can be diverted 180 degrees, left or right, with a center off position. The simplest directional control valve is the 2-way valve. 2 way pneumatic valve stops flow or allows flow. A water faucet is a good example of a 2-way valve. A water faucet allows flow or stops flow by manual control.

2018年7月3日星期二

JELPC High Pressure Solenoid Valves

Many high pressure solenoid valve manufacturers and suppliers can supply a complete high pressure solenoid valve solution for most safe area . High pressure brass solenoid valves, high pressure Stainless steel solenoid valves and high pressure coaxial solenoid valves are available in both functions 2/2 way (2 port 2 position)and 3/2 way (3 way 2 position valve) with operation in both direct acting or pressure/servo assisted suitable for liquid or gas media for pressures up to and exceeding 500 bar.

2018年6月19日星期二

JELPC offers a variety of Solenoid Valves

JELPC offers a variety of models with different configurations and capabilities, making it easy to find the right Solenoid Operated Valve for your unique application. A very common method of operating directional valves in a pneumatic system is with Solenoid Operated Valves. Recommended for use in systems requiring higher flow rates, a direct acting solenoid is mounted on a larger pneumatic valve and acts as a pilot operator. Upon actuation of the solenoid, pilot pressure shifts the larger valve, directing flow from the input port through the output port.   

2018年4月23日星期一

Standard air cylinder Precautions

The standard air cylinder should be noted when installing and adapting:

1.When the load changes in the work, the cylinder with abundant output should be selected.

2. In high temperature or corrosive conditions, the corresponding high temperature or corrosive cylinder should be selected;

3. In the case of large humidity and dust, or where there are water droplets and welding slag, the cylinder should adopt the protective measures to take a sigh.

4. Before the cylinder is connected to the pipe, it is necessary to know the stolen goods in the pipe and prevent the debris from entering the cylinder;

5. The medium of the cylinder shall be filtered by the filter core of 40um and above to be used;

6. In low temperature environment, anti-freeze measures should be taken to prevent water freezing in the system.

7. Before the cylinder is used, it should be operated by no-load test. Before operation, the buffer should be adjusted to the minimum I, and gradually give up, so as not to damage the cylinder;

In the working process, the cylinder should avoid the side load as much as possible, so as to maintain the normal operation of the cylinder and extend the service life;

It is not suitable for the cylinder to be removed for a long time. It should be noted that the surface is rustproof, and the inlet and outlet should prevent the blocking cap.

2018年3月30日星期五

Pneumatic control components

Pneumatic control components are important components of pressure, flow, flow direction and sending signal of compressed air, which are important components of pneumatic circuits and systems. The pneumatic control is known as the pneumatic valve, or valve.

2018年3月21日星期三

The working principle of the steam solenoid valve.

1. The steam solenoid valve is the direct pilot type solenoid valve for the step action, which can be divided into the normal closed solenoid valve and the normally open solenoid valve according to the difference of the opening and closing state when the power is off.

2. The steam solenoid valves, normally closed steam coil after electrify, armature vice valve under the effect of electromagnetic force to drive the valve plug, fluid by the deputy valve on the main valve cup run, reducing the role, the pressure of the main valve cup when the main valve cup pressure was reduced to a certain value, the armature drives the main valve cup, and by using pressure difference and make the main valve cup opening, medium circulation. When the coil is out of power, the electromagnetic force disappears, and the armature is reset due to gravity. At the same time, depending on medium pressure, the main auxiliary valve can be closed tightly.

3. Normally open steam solenoid valves, steam coil electricity due to the suction effect, after moving iron core down, the deputy valve plug pressure, the deputy valve closed, pressure rise within the main valve cup, when the pressure rises to a certain value, the main valve cup of fluctuation pressure difference, due to the electromagnetic effect, moving iron core loss of the main valve cup, the pressure the main valve seat, the valve closed. When the coil is out of power, the electromagnetic suction is zero, the auxiliary valve plug and the iron core are lifted by the spring, the auxiliary valve is opened, the main valve cup is pushed up by the pressure difference, the main valve is opened and the medium is in circulation.

2018年2月8日星期四

Heater Valve Products

A defective heater is a big problem especially during winter. You and your passengers could experience a "chilling" inconvenience when the part becomes faulty on a bleak morning ride. See, you could get frostbites without the warmth provided by the heater. With this kind of problem, too, you're most likely to catch colds if you're going on a long trip. So before heading out for the road on a cold day, remember to check your car heater first. If there's a damaged part, replacement must be done immediately. The 1 is one of the most important components that drivers need to check since it's directly involved in the distribution of hot air inside the cabin. This 1 is connected to a slide, lever, or dial on the dashboard. By flicking any of these, the driver is able to control the amount of coolant that the valve directs to the heater core. To inspect the valve, you have to do a bit of searching because it's found at the back portion of the engine bay. Now, when this valve gets damaged, the flow of hot air may cease. And the worst thing that could happen is that there won't be any warm air flowing in your car's interior. To avoid this hassle, you must find a high-quality heater valve replacement as soon as possible. For auto parts of superior quality, shop only at Auto Parts Warehouse. You'll surely get the best value for your money if you buy replacement parts from us.

2018年1月17日星期三

Electric solenoid valves

Electric solenoid valves is an industrial equipment controlled by electromagnetic control. It is an automatic basic element for controlling fluid. Electric solenoid valves belongs to actuator, and is not limited to hydraulic and pneumatic. Adjust the direction, flow, speed and other parameters of the medium in the industrial control system. The solenoid valve can cooperate with different circuits to achieve the expected control, and the accuracy and flexibility of the control can be guaranteed. There are many kinds of solenoid valves. Different solenoid valves play a role in different positions in the control system. The most common ones are one-way valve, safety valve, directional control valve, speed regulating valve and so on.