one is to use it to ignite the main burner; second is to use its uninterrupted heated thermocouple. Thermocouple is a heat can be converted into electrical energy components, installed next to the fire, the heat generated by its current control solenoid hydraulic cutting machine, open fire in the supply channel, so as to achieve the maintenance supply, continued to ignite the fire purposes. Water heaters used for a period of double hose connector time, prone to fire and flame failure can not be sustained. Its causes and treatment methods are as follows.
The gas fire unreasonable or can not maintain the channel conduction is the root cause of the fault.skiving machine If the thermocouple or the solenoid valve failure, fire or clogged nozzles will result in the supply passage barrier. When the thermocouple poor performance, even though it burned red, still no release after the fire when the ignition hand, can not hear the sound operation of the solenoid valve. In addition to external thermocouple failure, cracks or loose electrode leads are not likely to result in sustained ignition failure. If the hand release missing after the fire, but could hear the sound of the solenoid valve is released, it is clogged nozzle, then fire supply pipe can be removed with fine copper wire poke at the dirt can clog. If you have a fire after the hand release, but soon after automatically extinguished, it is caused by reason of the thermocouple. Can try to re-adjust the position of its best heat generally able to troubleshoot.