Control valve consists of two major assemblies components: body assembly and actuator assembly (or actuator systems), is divided into four series: single-seat series control valves, control valves seater series, sets cylinder series control valves and self-series control valve.
2015年2月6日星期五
Gas heater valve lifting requirements
Should be used at high intensity, long enough rope fixed to the lifting screw, ensure the rope angle of less than 60 °, lifting; Gas Heater Valve in the lifting, tying the sling is not allowed in the gas heater valve end cap on the gas heater valve neck, or gearing To move smoothly to avoid shocks.
Distance from the center of the pump outlet gas heater valve should be greater than 2000mm, if you can not meet this condition, to take rectification measures, where possible, the conditions should try to increase this distance in order to reduce the adverse effects of the turbulent flow regime pump outlet of the gas heater valve.
Some still some speakers pump outlet pipe, gas heater valve fully open, the disc should be within flare.
The butterfly patio heater valve body is mainly composed, transmission, hydraulic and electrical control components. Has the following main features:
The gas heater valve main seal type is: Stainless steel - stainless steel, and with three eccentric structure, so reliable sealing performance, and the disc more closed more tightly, easy to disengage; ring made of stainless steel, corrosion resistance and long service life.
For lead-bearing non-oil self-lubricating bearings, with strong bearing capacity, wear resistance, friction resistance and other characteristics; shaft seal with self-tightening and other double-sealed, good sealing effect; disc shape with streamlined design, has a small Gas Control Valves coefficient of flow resistance (≤0.2), novel appearance, appearance and other characteristics.
In short, the accumulator tank hydraulic control slow closing check gas heater valve in the application of the pumping station, with easy operation, investment, quick, favorable energy efficiency and many other advantages, in a similar pump station application.
2015年2月3日星期二
The application of gas heater control valve positioner
Storage tank to replace the current pilot hydraulic control gas heater control valve in the heavy hammer hammer slow closing check Gas
Heater Control Valve in the accumulator tank, the weight becomes fluid accumulator potential, not only to save the consumption of the long-running support hammer energy, but also improves the performance of the hydraulic system of packing, while also ensuring the maintenance staff gas heater control valve runtime safety.
An accumulator tank hydraulic control slow closing check gas heater control valve application advantages
Storage tank hydraulic control slow closing check gas heater control valve control mechanism novel,patio heater control valve, rational design, small size, light weight, simple structure, functional, flexible and reliable operation, nice appearance, energy and materials, easy maintenance, easy to implement pump gas heater control valve interlock control and computer centralized control. When a power outage, you can shake off gas heater control valve manual pump. gas heater control valve opening and closing, the action is very convenient.
Storage Tank slow closing hydraulic control gas heater control valve back to the structural features only
Storage tank hydraulic control gas heater control valve of choice back slow closed
Combined with the design requirements and operational characteristics of the pumping station, storage tank fluid Propane Control Valve we used both slow closing check gas heater control valve and check gas heater control valve function, is a good set can be adjusted according to a pre-programmed, two-stage (first fast off a certain angle, then slowly close the remaining angle) off action to eliminate water hammer damage ideal for pipe network control equipment.
An accumulator tank hydraulic control slow closing check gas heater control valve application advantages
Storage tank hydraulic control slow closing check gas heater control valve control mechanism novel,patio heater control valve, rational design, small size, light weight, simple structure, functional, flexible and reliable operation, nice appearance, energy and materials, easy maintenance, easy to implement pump gas heater control valve interlock control and computer centralized control. When a power outage, you can shake off gas heater control valve manual pump. gas heater control valve opening and closing, the action is very convenient.
Storage Tank slow closing hydraulic control gas heater control valve back to the structural features only
Storage tank hydraulic control gas heater control valve of choice back slow closed
Combined with the design requirements and operational characteristics of the pumping station, storage tank fluid Propane Control Valve we used both slow closing check gas heater control valve and check gas heater control valve function, is a good set can be adjusted according to a pre-programmed, two-stage (first fast off a certain angle, then slowly close the remaining angle) off action to eliminate water hammer damage ideal for pipe network control equipment.
2015年1月31日星期六
High pressure steel gas heater valve
Product structure type:
Gas Heater Control Valve is composed of a liquid-resistant synthetic rubber inner layer, middle layer, Ⅰ or Ⅱ or Ⅲ layer steel wire braid reinforcement, and excellent weathering performance synthetic rubber cover.
Product use:
Wire reinforced pilot operated safety valve is mainly used for mine hydraulic support, oil exploitation, suitable for construction, material handling, forging metallurgy, mining equipment, ships, injection molding machinery, agricultural machinery, tools and various industrial sectors mechanization and automation of gas heater valve delivery system with a certain pressure and temperature (e.g., mineral oil, soluble oil, hydraulic oil, fuel oil, lubricating oil) liquid, water-based liquid (e.g., emulsions, oil-water emulsion, water), gas and liquid transmission with.
Features:
1. Hose special selection made with synthetic rubber, has excellent oil resistance, heat aging resistance.
2. Hose bearing pressure, pulse superior performance.
3. tube combined with tight, use a soft, small Oven Safety Gas Valves deformation under pressure.
The hose has excellent resistance around the song and fatigue resistance.
5. The length of the large steel wire braided hose, φ32 length of 20 meters or more, φ25 can connect more than ten meters below even meters.
Temperature: Oil -40 ℃ - + 100 ℃, air -30 ℃ - + 50 ℃, water emulsion + below 80 ℃, please use the factory beyond specific products.
2015年1月28日星期三
Oven gas valve - Thread Standard
Oven gas valve - Thread Standard
A threaded classification
1. thread since the beginning of two kinds of internal and external threads;
2. Press the tooth shape can be divided into: 1) triangular thread 2) trapezoidal thread 3) rectangle thread 4) serrated thread;
3. Press the line fractal single thread and multiple thread;
4. Press the right-hand thread screw-direction points and two left-hand thread, dextral not marked, plus L-LH, such as M24 × 1.5LH;
5. Press uses different points are: Metric common thread, threaded Gas Grill Control Valve thread sealing, non-threaded gas heater control valve thread sealing, 60 ° tapered pipe thread, Metric taper thread, etc.
Two Metric common thread
1. Metric common thread with a capital M, said tooth type angle 2α = 60 ° (α, said tooth-type half-width);
2. Metric common thread pitch divided by the common thread of two coarse thread and fine teeth;
2.1 coarse gas heater valve thread pitch mark is generally not indicated, such as M20, said coarse thread; fine thread pitch mark must be identified, such as M30 × 1.5 represents fine thread, where the pitch is 1.5.
2.2. The common thread for the connection between gas patio heater valve mechanical parts and fastening, multi-threaded connection generally coarse thread, than the same nominal diameter of coarse thread fine thread strength is slightly higher, better self-locking performance.
Mark 3. Metric ordinary thread: M20-6H, M20 × 1.5LH-6g-40, where M represents the common thread Metric, 20, said the thread Gas Heater Control Valve nominal diameter 20mm, 1.5 represents pitch, LH, said L, 6H, 6g, said thread accuracy class, upper class code represents precision internally threaded lower accuracy level code, said external thread, 40, said screwing length
A threaded classification
1. thread since the beginning of two kinds of internal and external threads;
2. Press the tooth shape can be divided into: 1) triangular thread 2) trapezoidal thread 3) rectangle thread 4) serrated thread;
3. Press the line fractal single thread and multiple thread;
4. Press the right-hand thread screw-direction points and two left-hand thread, dextral not marked, plus L-LH, such as M24 × 1.5LH;
5. Press uses different points are: Metric common thread, threaded Gas Grill Control Valve thread sealing, non-threaded gas heater control valve thread sealing, 60 ° tapered pipe thread, Metric taper thread, etc.
Two Metric common thread
1. Metric common thread with a capital M, said tooth type angle 2α = 60 ° (α, said tooth-type half-width);
2. Metric common thread pitch divided by the common thread of two coarse thread and fine teeth;
2.1 coarse gas heater valve thread pitch mark is generally not indicated, such as M20, said coarse thread; fine thread pitch mark must be identified, such as M30 × 1.5 represents fine thread, where the pitch is 1.5.
2.2. The common thread for the connection between gas patio heater valve mechanical parts and fastening, multi-threaded connection generally coarse thread, than the same nominal diameter of coarse thread fine thread strength is slightly higher, better self-locking performance.
Mark 3. Metric ordinary thread: M20-6H, M20 × 1.5LH-6g-40, where M represents the common thread Metric, 20, said the thread Gas Heater Control Valve nominal diameter 20mm, 1.5 represents pitch, LH, said L, 6H, 6g, said thread accuracy class, upper class code represents precision internally threaded lower accuracy level code, said external thread, 40, said screwing length
2015年1月24日星期六
Installation Precautions gas heater control valve
Installation Precautions high pressure Heater Gas Valve
(1) hose in a mobile or stationary, and can not bend over, it can not be bent at the root, at least to start bending at 1.5 times its diameter;
(2) hose moved to the extreme position not pull it too tight, should be more relaxed;
(3) try to avoid the hose twisting deformation;
(4) hose as far as possible away from the heat radiating member, fashion necessary insulation boards;
(5) Avoid hose external damage, such as the use of the same long-term friction surface of the member;
(6) If the hose caused by excessive weight deformation, should support members.
Pre-installed piping
1 Introduction pipeline
(1) two-director and branch Gas Control Valve: From lubrication pump out until all the oil inlet distributor, relatively high under pressure. Usually cold drawn seamless steel gas heater valve, the material is 10 or 15 gauge steel. Severe corrosion of the pipe must not be used;
(2) to the pipeline: from the distributor to all lubrication points out the inlet (bearing hole), under pressure is relatively low. Usually drawn copper, easy to bend when the gas heater control valve. There is also cold drawn seamless steel or stainless steel pipe;
(3) the use of hose fittings encountered active site connections.
Piping layout requirements
(1) gas heater valve to try to avoid the heat radiation and cooling water temperature is too high or too low, such as spraying of the Department, particularly hose fittings;
(2) piping and other equipment should not affect the operation of the host, to be safe, reliable, easy to work, observations, maintenance;
(3) To smooth vertical and horizontal piping, neat appearance. As little as possible, or small-angle bend elbows, using a large arc, thus reducing oil flow resistance;
When the conflict (4) installation occurs, a small tube let bassoon, low-pressure Gas Heater Control Valve so that high-pressure pipe;
(5) the pipeline can not be contacted at the intersecting should spaced;
(6) parallel pipe joints should be staggered installation, to avoid affecting the installation and removal;
(7) In order to facilitate disassembly pipeline cleaning, the union should be properly installed, but to use less, reducing the possibility of leaks.
(1) hose in a mobile or stationary, and can not bend over, it can not be bent at the root, at least to start bending at 1.5 times its diameter;
(2) hose moved to the extreme position not pull it too tight, should be more relaxed;
(3) try to avoid the hose twisting deformation;
(4) hose as far as possible away from the heat radiating member, fashion necessary insulation boards;
(5) Avoid hose external damage, such as the use of the same long-term friction surface of the member;
(6) If the hose caused by excessive weight deformation, should support members.
Pre-installed piping
1 Introduction pipeline
(1) two-director and branch Gas Control Valve: From lubrication pump out until all the oil inlet distributor, relatively high under pressure. Usually cold drawn seamless steel gas heater valve, the material is 10 or 15 gauge steel. Severe corrosion of the pipe must not be used;
(2) to the pipeline: from the distributor to all lubrication points out the inlet (bearing hole), under pressure is relatively low. Usually drawn copper, easy to bend when the gas heater control valve. There is also cold drawn seamless steel or stainless steel pipe;
(3) the use of hose fittings encountered active site connections.
Piping layout requirements
(1) gas heater valve to try to avoid the heat radiation and cooling water temperature is too high or too low, such as spraying of the Department, particularly hose fittings;
(2) piping and other equipment should not affect the operation of the host, to be safe, reliable, easy to work, observations, maintenance;
(3) To smooth vertical and horizontal piping, neat appearance. As little as possible, or small-angle bend elbows, using a large arc, thus reducing oil flow resistance;
When the conflict (4) installation occurs, a small tube let bassoon, low-pressure Gas Heater Control Valve so that high-pressure pipe;
(5) the pipeline can not be contacted at the intersecting should spaced;
(6) parallel pipe joints should be staggered installation, to avoid affecting the installation and removal;
(7) In order to facilitate disassembly pipeline cleaning, the union should be properly installed, but to use less, reducing the possibility of leaks.
2015年1月20日星期二
Gas Heater Valve installation and maintenance of way
The installation and maintenance of way
Prevention of leakage of pipe joints in the gas heater valve, both the metal pipe coupling, or Oven Gas Valve, are prone to leakage problems. For card sets of pipe joints, mostly due to the pipe by a large external force or impact, so that the card sleeve loose or deformed pipe ends and cause leakage, you should check whether the card holder out of round, whether the defect edge, whether the pipe end in good condition and the extent of compression ferrule nut, while also eliminating external piping. For flared Gas Heater Control Valve, mostly due to excessive flaring, substandard quality requirements or repeatedly demolished, resulting in flaring deformation or cracks caused by leaks, then you can be re-flared front end truncated. If the top male and female cones pressure seal, which is mostly due to two cone leak damage, available grinders for grinding cone. In some by "о" or outer-ring seal by the end face of the gas heater valve, the leakage following reasons: "о" ring deformation caused by aging or leakage; "о" ring assembly is not in place, so that the two-plane connection when the pressure is uneven or "о" ring is cut cause leakage; "о" ring uncompacted, insufficient amount of elastic deformation caused by leakage; "о" mouth-ring groove just too deep and cause leaks. In this regard, the need to re-select the same diameter and cross-sectional coarse "о" rings, can also be sealed with a flat opening slot stop cutting or grinding to reduce the groove depth of mouth only, so "о" ring has sufficient amount of elastic Gas Control Valves (compression in general should be between 0.35-0.65mm). For the use of oil and rubber, wool felt, soft steel cardboard combination gasket sealant joints or pipe leaks, no matter what the material is, you should first check the seals without damage, deformation, aging and rough through the large, etc. and then take the appropriate measures.
Prevention of leakage of pipe joints in the gas heater valve, both the metal pipe coupling, or Oven Gas Valve, are prone to leakage problems. For card sets of pipe joints, mostly due to the pipe by a large external force or impact, so that the card sleeve loose or deformed pipe ends and cause leakage, you should check whether the card holder out of round, whether the defect edge, whether the pipe end in good condition and the extent of compression ferrule nut, while also eliminating external piping. For flared Gas Heater Control Valve, mostly due to excessive flaring, substandard quality requirements or repeatedly demolished, resulting in flaring deformation or cracks caused by leaks, then you can be re-flared front end truncated. If the top male and female cones pressure seal, which is mostly due to two cone leak damage, available grinders for grinding cone. In some by "о" or outer-ring seal by the end face of the gas heater valve, the leakage following reasons: "о" ring deformation caused by aging or leakage; "о" ring assembly is not in place, so that the two-plane connection when the pressure is uneven or "о" ring is cut cause leakage; "о" ring uncompacted, insufficient amount of elastic deformation caused by leakage; "о" mouth-ring groove just too deep and cause leaks. In this regard, the need to re-select the same diameter and cross-sectional coarse "о" rings, can also be sealed with a flat opening slot stop cutting or grinding to reduce the groove depth of mouth only, so "о" ring has sufficient amount of elastic Gas Control Valves (compression in general should be between 0.35-0.65mm). For the use of oil and rubber, wool felt, soft steel cardboard combination gasket sealant joints or pipe leaks, no matter what the material is, you should first check the seals without damage, deformation, aging and rough through the large, etc. and then take the appropriate measures.
2015年1月16日星期五
Card sets of gas heater valve installed
(1) according to the requirements of Chapter 9 of the need for pickling pipes should be pickled;
(2) according to the required length by sawing or patio heater gas valve machines and other equipment off the tube, and definitely not broken with solvent (such as flame cutting) or cutting wheel; remove the tube ends inside and outside round burrs, metal chips and dirt; removing rust-proof pipe fittings agents and dirt; but also to ensure the pipe roundness;
(3) the nut, ferrule has set into the tube, card sets Gas Control Valve the front edge (diameter end) from the mouth of the tube at least 3mm, then taper pipe into the connector body, until the top;
(4) Slowly tighten the nut, turn the gas safety burner valve until it does not move, then tighten the nut 2 / 3-4 / 3 laps;
(5) Remove the check card sets whether to cut the pipe, the location is correct. Card sets are not allowed to move axially to slightly rotate;
(6) Tighten the nuts again after passing inspection.